7-264
ASIND(P)
7.12.8 SIN
-1
operation on floating-point data (Double precision)
(ASIND(P))
ASIND(P)
Function
(1) The angle is calculated from the SIN (sine) value specified by is and its result is stored
into the device specified by .
(2) The SIN value designated by can be in the range from 1.0 to 1.0.
(3) The angle (operation result) stored at is stored in radian units.
For more information on the conversion between radian and angle data, see description of
RADD and DEGD instructions.
(4) When the operation results in -0 or an underflow, the result is processed as 0.
: SIN value of which the SIN
-1
(inverse sine) value is obtained or head number of the devices where the SIN
value is stored (real number)
: Head number of the devices where the operation result will be stored (real number)
Setting
Data
Internal Devices
R, ZR
J\
U\G
Zn
Constants
E
Other
Bit Word Bit Word
–– –– ––
–– –– –– ––
Universal
Basic
Process
High
performance
Redundant
LCPU
Command
Command
ASINDP
ASIND
ASINDP
ASIND S D
S D
S
D
S
D
S
D
)
SIN (
1
64-bit floating-point
real number
64-bit floating-point
real number
+3
S
+2
S
S
+1
S
+3
D
+2
D
D
+1
D
S
D

Table of Contents

Other manuals for Mitsubishi MELSEC Q Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi MELSEC Q Series and is the answer not in the manual?

Mitsubishi MELSEC Q Series Specifications

General IconGeneral
BrandMitsubishi
ModelMELSEC Q Series
CategoryController
LanguageEnglish

Related product manuals