1717
5
OUTLINES AND DIMENSIONS
PUMY-P60NKMU
PUMY-P60NKMU-BS
Unit : mm <inch>
ޓޓ࡮࡮࡮Refrigerant GAS pipe connection (FLARE):19.053/4F)
ޓޓ࡮࡮࡮Refrigerant LIQUID pipe connection (FLARE): 9.523/8F
+㧝࡮࡮࡮Indication of STOP VALVE connection location.
1
2
Min.
Min.
Min.
Min.
Service space
<Foundation bolt height>
Max.
The diagram below shows a basic example.
Explantion of particular details are
given in the installation manuals etc.
Dimensions of space needed
for service access are
shown in the below diagram.
Please secure the unit firmly
with 4 foundation (M10<W3/8>) bolts.
(Bolts and washers must be
purchased locally.)
1 FREE SPACE (Around the unit)
2 SERVICE SPACE
3 FOUNDATION BOLTS
4 PIPING-WIRING DIRECTIONS
Piping and wiring connections
can be made from 4 directions:
FRONT, Right, Rear and Below.
30<1-3/16>
150
<5-29/32>
500
<19-11/16>
500
<19-11/16>
10<3/8>
Example of Notes
Piping Knockout Hole Details
FOUNDATION
Drain hole
5-
:
33<1-5/16>)
Bottom piping hole
(Knockout)
154
<6-1/16>
136
<5-11/32>
45<1-25/32>
110<4-11/32>
160
<6-5/16>
160
<6-5/16>
160
<6-5/16>
81<3-3/16>
86<3-3/8>
Ground for the power supply
("GR"marking position)
Service panel
Handle for moving
2
1
Terminal connection
Left࡮࡮࡮For the power supply
Center࡮࡮࡮For the transmission line
Right࡮࡮For concentration control
( )
Ground for the transmission line
Ground for concentration control
Handle for moving
+
1ޓ450<17-23/32>
+
1ޓ393<15-15/32>
1079<42-15/32>
1050<41-11/32>
26<1-1/32>
369<14-17/32>
632<24-7/8>
1338<52-11/16>
362<14-1/4>
Scale 1:5
3/4 Conduit
attachment
When installing the conduit.
Set the attachment to the
inner side of each panel.
:
27.8<1-3/32>
:
22.2<7/8>
1/2 Conduit
attachment
100
<3-15/16>
24.7<31/32>
5<3/16>
22.5<7/8>
60<2-3/8>
Min. 1000mm<39-3/8> Min. 150mm<5-29/32>
Min. 10mm<3/8>Min. 10mm<3/8>
FREE
Rear piping hole
(Knockout)
Rear trunking hole
(Knockout)
Conduit hole
(
:
37<1-15/32>Knockout)
Conduit hole
(
:
24<15/16>Knockout)
60<2-3/8>
55<2-3/16>
55<2-3/16>27<1-1/16>
26<1-1/32>
5<3/16>
60<2-3/8>
73<2-7/8>
92<3-5/8>
75<2-15/16>
:
92
<3-5/8>
Right trunking hole
(Knockout)
Conduit hole
(
:
37<1-15/32>Knockout)
Conduit hole
(
:
24<15/16>Knockout)
Right piping hole
(Knockout)
73<2-7/8> 60<2-3/8>
5<3/16>
29<1-5/32>
27<1-1/16>
26<1-1/32>
92
<3-5/8>
53<2-3/32> 60<2-3/8>
55<2-3/16>
92<3-5/8>
:
92
<3-5/8>
Conduit hole
(
:24<15/16>Knockout)
Front piping hole
(Knockout)
Front trunking hole
(Knockout)
Conduit hole
(
:
37<1-15/32>Knockout)
60<2-3/8>
55<2-3/16>
26<1-1/32>
5
<3/16>
60
<2-3/8>
73<2-7/8>
75<2-15/16>
92<3-5/8>
27<1-1/16> 55<2-3/16>
:
92
<3-5/8>
Air Discharge
Rear Air Intake
Side Air Intake
2-12×36 Oval holes
(Foundation Bolt M10<W3/8>)
2-U Shaped notched holes
(Foundation Bolt M10<W3/8>)
Installation Feet
25<31/32>
417<16-13/32>
42
<1-21/32>
61<2-13/32>
70
<2-3/4>
28<1-3/32> 19<3/4>370<14-9/16>
225
<8-27/32>
600<23-5/8>
225
<8-27/32>
330<13>
53<2-3/32>
56<2-7/32>
40<1-9/16>
0
Rear piping cover
Front piping cover
Air intake
Side Air IntakeRear Air Intake
Handle for
moving
Handle for
moving
OCH502C