SW1 setting
12345678
01110001
11110001
10001001
01001001
11001001
00101001
10101001
01101001
11101001
00011001
10011001
01011001
11011001
00111001
10111001
01111001
11111001
00000101
01010101
11010101
00110101
10110101
01110101
11110101
00001101
10001101
01001101
11001101
00101101
10101101
01101101
11101101
00011101
High-pressure sensor data at time of abnormality delay
kgf
/
cm
2
OC SC (cooling) at time of abnormality delay °C
TH4 sensor data at time of abnormality delay °C
TH6 sensor data at time of abnormality delay °C
TH3 sensor data at time of abnormality delay °C
TH8 sensor data at time of abnormality delay °C
IC1 SC/SH at time of abnormality delay °C
IC2 SC/SH at time of abnormality delay °C
IC3 SC/SH at time of abnormality delay °C
IC4 SC/SH at time of abnormality delay °C
IC5 SC/SH at time of abnormality delay °C
IC6 SC/SH at time of abnormality delay °C
IC7 SC/SH at time of abnormality delay °C
IC8 SC/SH at time of abnormality delay °C
IC9 SC/SH at time of abnormality delay °C
IC10 SC/SH at time of abnormality delay °C
IC11 SC/SH at time of abnormality delay °C
IC12 SC/SH at time of abnormality delay °C
ROM version monitor
ROM type
Check sum mode
IC1 LEV opening pulse at time of abnormality delay
IC2 LEV opening pulse at time of abnormality delay
IC3 LEV opening pulse at time of abnormality delay
IC4 LEV opening pulse at time of abnormality delay
IC5 LEV opening pulse at time of abnormality delay
IC6 LEV opening pulse at time of abnormality delay
IC7 LEV opening pulse at time of abnormality delay
IC8 LEV opening pulse at time of abnormality delay
IC9 LEV opening pulse at time of abnormality delay
IC10 LEV opening pulse at time of abnormality delay
IC11 LEV opening pulse at time of abnormality delay
IC12 LEV opening pulse at time of abnormality delay
1
2345 6
78
Display on the LED1, 2 (display data)
Display of data from high-pressure sensor,
all thermistors, and SC/SH at time of
abnormality delay
Display of version data of ROM
Display of ROM type
Display of check sum code of ROM
Display of opening pulse of indoor LEV
at time of abnormality
-99.9 – 999.9
0 – 2000
No.
Display mode Notes