Description of the unit
14 Installation instructions
Model: FKECOD
Size 615 621 115 121 215 221
Voltage (V) 400
Connected load (kW) 10.4 20.9 15.9 30.5 31.7 60.9
Fuse (A) 3 x 16 3 x 35 3 x 25 3 x 50 3 x 50 3 x 100
Voltage (V) 415
Connected load (kW) 11.2 22.5 17.1 32.8 34.1 65.5
Fuse (A) 3 x 16 3 x 35 3 x 25 3 x 50 3 x 50 3 x 100
Voltage (V) 440
Connected load (kW) 10.4 20.9 15.8 30.5 31.5 60.9
Fuse (A) 3 x 16 3 x 35 3 x 25 3 x 50 3 x 50 3 x 100
Voltage (V) 480
Connected load (kW) 12.3 20.9 18.9 32.6 37.6 65.1
Fuse (A) 3 x 16 3 x 35 3 x 25 3 x 50 3 x 50 3 x 100
Soft water connection
Type of water Soft water, cold
Carbonate hardness
CaCO
3
(mmol/l (°dH))
< 0,9 (5)
Chloride Cl (mg/l) < 50
Iron Fe (mg/l) < 0.1
Connection pressure (kPa
(bar))
200 (2) — 600 (6)
Connection (") R 3/4
Tap water connection
Type of water Tap water, cold
Carbonate hardness
CaCO
3
(mmol/l (°dH))
< 4 (22)
Connection pressure (kPa
(bar))
200 (2) — 600 (6)
Connection (") R 3/4
Water consumption for steaming
Soft water (l/h) 16 21 18 24 36 48
Water consumption for Combisteaming
Soft water (l/h) 3,5 4,6 4 5,3 8 10,6
Water consumption for WaveClean cleaning program
Soft water (l) 3
Tap water (l) 32
Wastewater connection
Wastewater type Dirty water, maximum 80 °C
Connection to unit (mm) 50
Maximum length (m) 1