EasyManua.ls Logo

MKN FlexiCombi MagicPilot FKECOD615 - Connecting Softened Tap Water to both Connections

MKN FlexiCombi MagicPilot FKECOD615
48 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Connecting the unit
38 Installation instructions
6.5.2 Connecting softened tap water to both connections
If only softened tap water is available at the installation site, use a T-
piece to connect both water connections on the unit to each other.
a
b
c
d e
f
g
h
Image: Connecting softened tap water to both connections
a Softened tap water e Tap water connection
b Backflow preventer f Dirt filter
c Connection line g T-piece
d Softened tap water connection h Seal
Requirement Water pressure complies with the specified range (see "Equipment
and connection data")
Backflow preventer installed
The connection line is pressure-tight and suitable for tap water
1. Connect the connection line to the tap water valve for soft water
using a seal.
2. Flush the connection line thoroughly.
3. Insert dirt filters into the water connections on the unit.
4. Connect the T-piece to the unit.
5. Connect the connection line for soft water to the T-piece using a
seal.
6. Open the tap water valve and check the threaded connectors for
leaks.
7. Fill out the Commissioning report.
10013865-0AIBE-B

Table of Contents