www.miinet.com Moore Industries-International, Inc.
- 74 -
User’s Manual
224-790-00K
May 2018
Programmable Limit Alarm Trips
SPA
2
SECTION 5
Figure 5.9. SPA
2
TPRG Trimming Hook-Up Diagram For PC Configuration
PC
MILLIVOLT
SOURCE
OR T/C
SIMULATOR
OHMS
OR RTD
SIMULATOR
Universal
Power
Supply
GND
AC/DC
AC/DC
+
- MULTIMETER
OR
DCS
TO SERIAL
(COM) PORT
OF PC
To USB
(COM)
Port of PC
CURRENT OUTPUT SOURCE
+
+
EXTERNAL
POWER
SUPPLY
+
CURRENT OUTPUT SINK
MULTIMETER
OR
DCS
MULTIMETER
OR
DCS
+
MULTIMETER
OR
DCS
VOLTAGE OUTPUT
HOOK-UPS FOR OUTPUT TRIMMING