Input | 4-20mA |
---|---|
Output | 4-20 mA, 0-20 mA, 0-5 V, 0-10 V, ±5 V, ±10 V |
Output Current | 4-20mA |
Operating Temperature | -40°C to +85°C |
Enclosure Rating | NEMA 4X |
Explanation of hazard alert symbols used in the manual.
Defines key terms related to process alarms and relays.
Outlines the steps for performing a bench check on the unit.
Step-by-step guide for bench checking the HLPRG model.
Step-by-step guide for bench checking the TPRG model.
Safety rules and general practices for making electrical connections.
Safety precautions for installing in potentially explosive atmospheres.
Capturing input zero and full scale values using external equipment.
Setting display modes, decimal places, filters, and broken wire detection.
Configuring alarm latching behavior and fail-safe modes.
Configuration of password protection and access control.
Step-by-step guide to setting the input type for HLPRG models.
Setting analog output damping and fail mode.
Setting zero and full scale values for the analog output.
Steps to set or change the unit's access password.
Step-by-step guide to selecting and configuring TPRG sensor types.
Setting the zero and full scale values for input display.
Setting trim mode (factory or user-defined) for input accuracy.
Adjusting analog output accuracy to match receiving devices.
Introduction to setting up the unit's alarm functions.
Steps to configure fault alarms for detecting malfunctions.
Steps to configure alarms for detecting rapid input value changes.
Steps to configure alarms for process values outside a defined range.
Steps to configure alarms for when input values stop changing.
Steps to configure trip alarms, including setting points and delays.
Detailed steps for configuring fault alarms using the PC software.
Detailed steps for configuring stuck input alarms using the PC software.
Setting input parameters like type, range, filters, and broken wire detection.
Setting up alarm parameters like type, trip points, and options via PC.
Detailed steps for configuring band alarms using the PC software.
Setting up analog output parameters like range, damping, and fail mode.
Adjusting and testing the analog output using the PC software.
Setting input scaling parameters using the PC software.
Creating and configuring custom curves for output linearization via PC.
Using the software to trim input accuracy for better measurements.
Detailed steps for configuring trip alarms using the PC software.
Detailed steps for configuring ROC alarms using the PC software.