EasyManua.ls Logo

Motorola APX 3000

Motorola APX 3000
474 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5-16 Troubleshooting Charts: DC Supply Failure
5.4.2 DC Supply 3.6 Volt Failure
V_SW_5
Is fuse intact
(not blown)?
Replace Fuse
Verify UNSW_B+ at
test point: F_UNSW_B+
Verify L200, C202
and C203 is good
Verify SW_B+
at C6524
Is 6 < V < 9
Verify Q6501
Check U6504 circuitry.
Enable input
present?
Check U6508 loading
V_SW_3.60
MAKO damaged. Replace
MAKO
Is radio current
>100mA
Check U201 is loading
V_SW_3.60
Yes
Yes
Yes
Yes
Yes
No
No
No
No
No

Table of Contents

Other manuals for Motorola APX 3000

Related product manuals