Scanning 2 - 5
Table 2-5
CR0078-P Cradle LED Definitions
LED Indication
Green Solid Cradle is powered (scanner not in cradle).
Fully charged scanner (scanner in cradle).
Green Flash Charging scanner (scanner in cradle).
Red Flash Transmission error.
Red Solid Charge error (scanner in cradle).
Blue Solid When
Page Button
is enabled and pressed (see
Page Button on page 4-25
),
the cradle LED turns blue when the scanner is out of the cradle.
Amber Flash Critical battery temperature fault. Battery is above or below normal operating
temperature.
If this occurs, do not use the digital scanner and move the digital scanner to a
location within normal operating temperature. The digital scanner can remain in
the cradle while the battery warms or cools to normal operating temperature.
Note: For appropriate charging temperatures, see
Table 3-3 on page 3-10
.