182
Time-Out Timer
Field Function Location
Time-Out Timer Sets timer duration radio-wide CHANGE:RADIO:SYS CONFIG
Time-Out Timer Enables Time-Out Timer for the current
channel
CHANGE:CHANNEL:OPTIONS
Time-Out Timer
Alert
Enables Alert Tone when timer expires CHANGE:RADIO:ALERT TONE CONFIG
Time-Out Timer
Pre-alert
Enables warning tone four seconds before
timer expires
CHANGE:RADIO:ALERT TONE CONFIG
Battery Saver
Field Function Location
Battery Saver Enables Battery Saver for the current channel CHANGE:CHANNEL:OPTIONS
Sleep Period Time radio will be dormant in Battery Saver
on Quik-Call II channel
CHANGE:RADIO:SIG:QUIK-CALL II
CS Sleep Period Time radio will be dormant in Battery Saver
on CSQ Channel
CHANGE:RADIO:SYS CONFIG
PL Sleep Period Time radio will be dormant in Battery Saver
on PL Channel
CHANGE:RADIO:SYS CONFIG
Battery Saver PL
Lockout
Disables decoding of PL until Carrier drops
after wrong PL is detected
CHANGE:RADIO:SYS CONFIG
Option•Mate
Field Function Location
Plug-in Board Changes radio’s audio routing path to route
Tx and Rx audio through Option Board
CHANGE:RADIO:CONFIG:OPTION•MATE
Controller Board Initialization
Field Function Location
Serial Number Inputs serial number during initialization
of a replacement Controller Board
SERVICE: CONTROLLER UNIT