6 - 14 MC1000 with Windows CE 5.0 Integrator Guide
TCM Error Messages
TCM validates the cells in the partition table when the Execute button is clicked. Cells highlighted in red contain an
error. Partition loading is disabled until all errors are corrected.
Table 6-3
TCM Error Messages
Error Description/Solution
Failed to build images: flash file
system DLL not loaded!
TCM could not load the DLL required to build images for the targeting flash file
system. Reinstall TCM or recover the DLL.
Failure finding directory xxx Building process failed because directory xxx was not found.
Failure creating volume Building process failed because TCM could not create a certain disk volume.
Failure adding system file to image Build process failed because TCM failed to add a certain system file to the
disk image.
INVALID PATH The path for the image file to build is not valid.
Nothing Selected To Build In the Config Build window, no item is selected to build.
Illegal ESS ID In the Build ESSID Partition window, no ESS ID was entered or the ESS ID
entered was illegal.
Disk Full TCM failed to create Hex image file at the selected path. Check available disk
space.
Target Disk Full Build process failed because TCM failed to add file to the image of a disk
volume. Remove some files or increase the disk size.
Hex file is READ ONLY The Hex image file to be created exists and is read-only. Delete the existing
file or change its attribute.
Error opening the file xxx with write
access
TCM could not open file xxx with write access. Check if file is in use.
Failure creating binary file TCM failed to open/create an intermediate binary file.
Hex File To load is missing or
invalid
In Load Terminal window, the file selected to load has invalid status.
Could not locate terminal name in
TCM.ini file
While loading the Script Properties window, TCM could not find the TCM.ini
section corresponding to the mobile computer type specified by the current
opening script. Either TCM.ini or the script file is invalid.
Incorrect disk sizes in TCM.ini file The total disk size specified in the script does not match the total disk size
defined in the corresponding TCM.ini section. Check if the script is corrupt or
the TCM.ini has changed after the script was created.
INVALID DIRECTORY In Script Properties window, the selected System File Path is not a valid
directory.
One of the disk sizes is one sector
in size
In Script Properties window, one of the disks is too small (one sector in size).
This may cause problem while building images, especially when cushion is
enabled. Increase the disk size.

Table of Contents

Other manuals for Motorola MC1000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Motorola MC1000 and is the answer not in the manual?

Motorola MC1000 Specifications

General IconGeneral
BrandMotorola
ModelMC1000
CategoryHandhelds
LanguageEnglish

Related product manuals