CENELEC Approval
A series of models covering VHF and UHF
bands are approved by the “British Approval
Service for Electrical Equipment in Flammable
Atmospheres” (BASEEFA) for use in haz-
ardous environments. The approval rating for
these models is EEx ib IIC T4.
CENELEC models are marked with the
approval number EX94C2258X.
The following points MUST be noted to main-
tain approval:
ONLY Motorola batteries with part num-
ber NTN7148A may be used in a haz-
ardous environment. Radio and battery
are marked with a blue spot to aid iden-
tification.
Battery charging must occur ONLY in
non-hazardous areas.
Users are warned that batteries should
NOT be rubbed or cleaned with solvents
to avoid any risk of ignition due to the
build-up of electrostatic charges.
When the radio is used in a hazardous
area, it is recommended that either the
protective cover (Part No.3205500U01)
for the universal connector or an
approved accessory is fitted.
NO audio accessories may be connect-
ed to these radios UNLESS they are
approved by BASEEFA for use with
these radios.
An antenna with damaged insulation or
with a missing end cap must NOT be
used in a hazardous environment. It
MUST be repaired or replaced.