7. ADVANCED SETTING
Under do not execute the Datalogger function,
press the " SET Button " ( 3-7, Fig. 1 ) continuously at
least 1.5 seconds will enter the " Advanced Setting " mode.
then press the " SET Button " (3-7, Fig. 1 ) once a while
in sequence to select the six main function, the lower
display will show :
DATA…… Set clock time ( Year/Month/Date, Hour/Minute/
Second )
SP-T......... Set sampling time ( Hour/Minute/Second )
POFF....... Auto power OFF management
BEEP.......
.
Set beeper sound ON/OFF
DEC..........Set SD card Decimal character
SD- F........ SD memory card Format
A ………. Select the Frequency weighting to A or C
During execute the " Advanced Setting " function
,
if press " HOLD Button " ( 3-2, Fig. 1 ) once will exit
the " Advanced Setting " function, the LCD will
return to normal screen.
7-1 Set clock time ( Year/Month/Date,
Hour/Minute/ Second
)
When the lower display show " DATE "
1)
Use the " Button " ( 3-5, Fig. 1 ) or "
Button "
( 3-6, Fig. 1 ) to adjust the value ( Setting start from
Year value ). After the desired value is set, press the
" Enter Button " ( 3-8, Fig. 1 ) once will going to
next value adjustment ( for example, first setting
value is Year then next to adjust Month, Date, Hour,
Minute, Second value ).