ALTAIR 2X
47
Technical Data
GB
5 Technical Data
5.1 Technical Specifications
Weight 115 g (4 oz) (device with battery and clip)
Dimensions
(L x W x D)
87 x 55 x 48 mm (3.4 x 2.2 x 1.9 in) – with fastening clip
Alarms Two super bright LEDs with 320° viewing angle and a loud audible
alarm, vibrating alarm
Volume of
audible alarm
95 dB typical at 30 cm distance
Displays Large display of measured values
Battery type Non-rechargeable Lithium battery.
Only replace with: battery as listed in section 7.
Battery life 6 months to 12 months, depending on device settings,
environmental conditions and general care and use.
At very low and very high temperatures the useable battery runtime
can be significantly reduced.
Sensor Electrochemical
Warm up time 1 minute during start-up procedure
Temperature
range
Normal Operating Range -10°C to 40°C (14°F to 104°F)
Extended Operating Range -20°C to 50°C (-4°F to 122°F)
Short-term exposure -40°C to 60°C (-40°F to 140°F)
Storage 0°C to 40°C (32°F to 104°F)
Vibrating Alarm 0°C to 50°C (32°F to 122°F)
Intrinsic Safety (ATEX, IEC, CSA) -40°C to 60°C (-40°F to 140°F)
At extremely low temperatures (below -20°C), the display can have
a very slow update rate and can become hard to read.
Atmospheric
Pressure Range
80 to 120 kPa (11.6 to 17.4 PSIA)
Humidity range 15 % to 90 % relative humidity, non-condensing
5 % to 95 % relative humidity intermittent
Dust and spray
protection
IP 67