Safety Regulations
GB
1.2 Liability Information
MSA accepts no liability in cases where the product has been used inappropri-
ately or not as intended. The selection and use of this product must be under
the direction of a qualified safety professional who has carefully evaluated the
specific hazards of the jobsite where it will be used and who is completely
familiar with the product and its limitations. The selection and use of this product
and its incorporation into the safety scheme of the jobsite is the exclusive
responsibility of the Employer.
Product liability claims, warranties also as guarantees made by MSA with
respect to the product are voided, if it is not used, serviced or maintained in
accordance with the instructions in this manual.
1.3 Safety and Precautionary Measures
Use Device only for Assigned Gases
The device must be used only for gases for which a sensor is installed in the
device.
Check Function
Before each day’s use, check the function of the device ( chapter 3.5).
MSA recommends carrying out a routine inspection prior to each day’s use.
Perform a Bump Test
Bump test frequency is often stipulated by national or corporate regulations;
however, bump testing before each day´s use is generally the accepted best
safety practice and is therefore MSA’s recommendation. The device must pass
the bump test. If it fails the test, perform a calibration before using the device.
Perform a bump test more frequently if the device is subjected to physical shock
or high levels of contaminants.
Check Function and Alarm before Each Use
In case of failed function tests, the device must be removed from use.
WARNING
The following safety instructions must be followed implicitly. Misuse can result