Technical Data
GB
Performance Specifications
Sensor Range Resolution
Reproducibility
Normal
Temperature Range
Extended
Temperature Range
CO Carbon
Monoxide
0-1999 ppm 1 ppm +/-5 ppm or 10% of
reading, whichever is
greater
+/-10 ppm or 20% of
reading, whichever is
greater
CO Carbon
Monoxide
High Concentration
0-9999 ppm 5 ppm +/-10 ppm or 10% of
reading, whichever is
greater
+/-25 ppm or 20% of
reading, whichever is
greater
H
2
S Hydrogen
Sulfide
0-200 ppm 1 ppm +/-2 ppm or 10% of
reading, whichever is
greater
+/-5 ppm or 20% of
reading, whichever is
greater
H
2
S Low
Concentration (CO/
H
2
S-LC sensor)
0-100.0 ppm 0.1 ppm +/-2 ppm or 10% of
reading, whichever is
greater
+/-5 ppm or 20% of
reading, whichever is
greater
H
2
S Low
Concentration (H
2
S-
LC/SO
2
-sensor)
0-100.0 ppm 0.1 ppm +/-2 ppm or 10% of
reading, whichever is
greater
+/-5 ppm or 20% of
reading, whichever is
greater
Cl
2
Chlorine 0-10.0 ppm 0.05 ppm +/-0,2 ppm or 10% of
reading, whichever is
greater
+/-0,5 ppm or 20% of
reading, whichever is
greater
NH
3
Ammonia 0-100 ppm 1 ppm +/-2 ppm or 10% of
reading, whichever is
greater
+/-5 ppm or 20% of
reading, whichever is
greater
NO
2
Nitrogen
Dioxide
0-50.0 ppm 0.1 ppm +/-2 ppm or 10% of
reading. whichever is
greater
+/-3 ppm or 20% of
reading, whichever is
greater
SO
2
Sulphur
Dioxide
0-20.0 ppm 0.1 ppm +/-2 ppm or 10% of
reading, whichever is
greater
+/-3 ppm or 20% of
reading, whichever is
greater