Accessories included in the type examination:
l
Remote calibration adapter CalGard, part.-no. 10150921
l
Sensor Gard, part.-no. 10113033
l
Flow through adapter, part.-no. 10113031
l
Calibration cap, part.-no. 10112789
PrimaX I
Manufacturer:
MSA Europe GmbH
Schlüsselstrasse 12
CH-8645 Rapperswil-Jona
Product: PrimaX I
EU-Type Examination Certificate:
BVS 10 ATEX E009 X
by DEKRA Testing and Certification GmbH (NB 0158)
Standards:
EN 60079-0:2012 + A11:2013, EN 60079-11:2012,
EN 60079-0:2018 (in preparation)
Performance EN 50104:2010, EN 50271:2018
Gas:
Oxygen: 0-10% (V/V), 0-25% (V/V)
Other gases: PFG 11 G 001: EN 45544 -1:1999; EN 45544 -2:1999
Tox: H2S: 0-20 ppm; 0-100 ppm;
CO: 0-100 ppm; 0-1000 ppm
Marking: Prima X I
II 1G Ex ia IIC T4 Ga
-40°C Ta +70°C
II 2D Ex ia IIIB T135°C Db
-40°C Ta +40°C
P
i
700mW, U
i
28V, I
i
100mA, L
i
= 0, C
i
= 0
Option:
HART Module Connector, only for temporary connection of an intrinsic safe
HART Field Communicator
P
o
700mW, U
o
28V, I
0
100mA, L
o
10µH, C
o
1nF
P
i
5mW, U
i
5V, I
i
1mA, L
i
= 0, C
i
= 0
Special conditions for safe use:
It is not allowed to open the key pad cover during usage in areas where EPL Ga, Group IIC is required.
Avoid electrostatic charge on the temporary used calibration cap when used for calibration.
Quality Assurance Notification: see Label
Year of Manufacture: see Label
Serial Nr.: see Label
45 PrimaX GB
7 Approvals

Other manuals for MSA PrimaX