Page #86 background imageLoading...
Page #86 background image
Figure 53
3.50
88.90
2.50
63.50
5.00
127
4.00
101.60
CLEARANCE SLOTS
FOR
1/4" SCREWS
(4 PLACES)
1.00
25.40
2.12
53.88
2.12
53.88
#10-32 MOUNTING
HOLES
(4 PLACES)
8.69
220.62
5.09
129.39
4.31
109.45
9.64
244.75
M25
12.76
324.21
3/4" NPT
XIR PLUS SENSORS MUST
BE MOUNTED HORIZONTALLY
13.71
348.34
M25
4.49
114.05
3.49
88.65
+DC (RED)
RS485+ (GRN)
RS485- (BLU)
-DC (WHT)
JB5000 BOARD
(FOR REMOTED SENSOR)
WHT
BLU
GRN
RED
BLU
WHT
GRN
RED
SHIELD
FROM
MAIN TRANSMITTER
CONNECTOR FROM
SENSOR
JB5000 MOUNTING BRACKET
MSA P/N 10206632
REMOTE JUNCTION BOX JB5000
CUSTOMER ____________________________
P.O. NO. ____________________________
MSA NO. _____________________________
LOCATION ____________________________
TAG NO. _____________________________
TOTAL NO. OF UNITS __________________
3/4" NPT
-DC(WHT)
RS485-(BLU)
RS485+(GRN)
+DC(RED)
XCELL SENSORS MUST
BE MOUNTED VERTICALLY
DOWN
LIFECYCLE STATE
REVISION
0
Production
sk3015-1066
REVISIONS
1234
8 7
6 5
56
78
4 3 2 1
A
B
C
D
A
B
C
D
SHEET SIZE
SK3015-1066
SHEET
D
None
SCALE:
CADD REF:
S.HALBROCK 3-18-2021
MANUFACTURING
J.HOFFMAN 3-19-2021
QUALITY ASSURANCE
J.HAVERSTICK 3-22-2021
PROJECT ENGR.
B.COOK 3-22-2021
CHECKED BY
WJE 3-17-2021
INSTALLATION OUTLINE,
JB5000
DRAWN BY DATE
NIOSH ATTR. DOC.: APPROVAL AGENCY CODE:
800000047043
JOB NO.
1 OF 1
sk3015-1066
THIS DRAWING IS THE PROPERTY OF MSA - THE SAFETY COMPANY AND IS MADE
AVAILABLE TO YOU IN CONFIDENCE AND SUBJECT TO THE FOLLOWING: NO
PERMISSION IS GRANTED TO PUBLISH, USE, REPRODUCE, TRANSMIT OR DISCLOSE
THIS DRAWING, OR ANY INFORMATION CONTAINED THEREIN TO OTHERS WITHOUT
THE PRIOR WRITTEN CONSENT OF MSA - THE SAFETY COMPANY EXCEPT FOR THE
MANUFACTURE OF ARTICLES FOR MSA - THE SAFETY COMPANY.
MSA STANDARD SHOP PRACTICES APPLY
DO
NOT
SCALE
DWG.
www.MSAsafety.com
THIRD-ANGLE
PROJECTION
US Ultima X5000 Gas Monitor 86

Other manuals for MSA ULTIMA X5000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the MSA ULTIMA X5000 and is the answer not in the manual?

MSA ULTIMA X5000 Specifications

General IconGeneral
Ingress ProtectionIP66/67
SensorsElectrochemical, infrared
CommunicationHART, Modbus
Target GasesCombustible gases, toxic gases, oxygen
ApprovalsATEX, IECEx, UL, CSA, SIL 2

Related product manuals