8.19.2 Battery-charging generator – Check
Preconditions
Engine is stopped and starting disabled.
WARNING
Compressed air gun ejects a jet of pressurized air.
Risk of injury to eyes and damage to hearing, risk of rupturing internal organs!
Never direct air jet at people.
Always wear safety goggles/face mask and ear defenders.
Checking battery-charging generator
Item Findings Measure
Ventilation areas (arrows) Clean None
Ventilation areas (arrows) Contaminated Clean
Cleaning battery-charging generator
Note: Dry-clean battery-charging generator only. Do not insert sharp objects in the ventilation openings.
1. Remove coarse contamination from battery-charging generator.
2. Blow out ventilation areas (arrows) with compressed air until there is no more dust development.
MS150049/04E 2017-04 | Battery-Charging Generator | 137