Number of cylinders 16
Displacement, total Liters 31.84
Number of inlet valves per cylinder 2
Number of exhaust valves per cylinder 2
Lube oil system
Number of cylinders 16
Lube oil operating temperature before engine, from R °C 80
Lube-oil operating temperature before engine, to R °C 85
Lube oil operating pressure before engine, from R bar 6.0
Lube oil operating pressure before engine, to R bar 6.5
Fuel system
Number of cylinders 16
Fuel pressure at engine inlet connection, min. (when engine is starting) L bar -0.3
Fuel pressure at supply connection to engine, min. (when engine is run‐
ning)
L bar -0.3
Fuel pressure at supply connection to engine (when engine is starting),
max.
L bar +0.5
Fuel supply flow, max. R Liters/min 24
General operating data
Number of cylinders 16
Firing speed, from R rpm 100
Firing speed, to R rpm 120
Starter (electric)
Number of cylinders 16
Rated starter voltage (standard design) R V= 24
Starting equipment (with air starter motor)
Number of cylinders 16
Starting-air pressure before starter motor, min. R bar 24
Starting-air pressure before starter motor, max. R bar 30
MW15550/06E 2012-02 | Technical Data | 121
TIM-ID: 0000003104 - 002