7.8.3 Fuel system – Venting
Preconditions
Engine is stopped and starting disabled.
WARNING
Fuels are combustible.
Risk of fire and explosion!
Avoid open flames, electrical sparks and ignition sources.
Do not smoke.
Venting fuel system
1. Unlock fuel priming pump, unscrew handle.
2. Open vent plugs on filter head.
3. Operate the pump with the handle until bub‐
ble-free fuel emerges at the vent plugs.
4. Close vent plugs on filter head.
MW15550/06E 2012-02 | Task Description | 193