3.21 16V 2000 M50A engine data: Engine-mounted heat
exchanger, reference condition: Intake-air temperature 25 °C
Explanation
Abbrev. Meaning
DL Reference value: Continuous power
BL Reference value: Fuel stop power
A Design value
G Guaranteed value
R Guideline value
L Limit value, up to which the engine can be operated, without change (e.g. of power set‐
ting)
N Not yet defined value
- Not applicable
X Applicable
Reference conditions
Engine model 16V2000
M50A
Application group 3A
Intake-air temperature °C 25
Raw water inlet temperature °C 25
Barometric pressure mbar 1000
Site altitude above sea level m 100
Power-related data (power ratings are net brake power to ISO 3046)
Number of cylinders 16
Rated engine speed A rpm 1500
Continuous power ISO 3046 (10% overload capability, design power DIN
6280, ISO 8528)
A kW 664
General conditions (for maximum power)
Number of cylinders 16
Intake depression (new filter) A mbar 15
Intake depression, max. L mbar 50
Model related data (basic design)
Number of cylinders 16
Cylinder arrangement: V angle Degrees 90
Bore mm 130
Stroke mm 150
Displacement of a cylinder Liters 1.99
MW15550/06E 2012-02 | Technical Data | 99
TIM-ID: 0000003042 - 002