4.3 Operational checks
DANGER
Unguarded rotating and moving engine components.
Risk of serious injury – danger to life!
Take special care when working on a running engine.
WARNING
Engine noise above 85 dB (A).
Risk of damage to hearing!
Wear ear protectors.
Operational checks
Item Measure
Engine under load
Engine at nominal speed
Visually inspect engine for leaks and general condition;
Check for abnormal running noises and vibration;
Check exhaust color (→ Page 149).
Fuel prefilter Check fuel prefilter contamination indicator for max. admissible value
(→ Page 197).
Drain water and contaminants (→ Page 198).
Air filter Check signal ring position of contamination indicator (→ Page 206).
HT coolant pump Check relief bore for oil and coolant discharge and contamination
(→ Page 225).
Raw water pump Check relief bore for oil and water discharge and contamination
(→ Page 227).
Intercooler Check condensate drain (if applicable) (→ Page 203).
Engine oil Check engine oil level (→ Page 208).
MW15550/06E 2012-02 | Operation | 139
TIM-ID: 0000002274 - 005

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the MTU 8 V 2000 M51A and is the answer not in the manual?

MTU 8 V 2000 M51A Specifications

General IconGeneral
BrandMTU
Model8 V 2000 M51A
CategoryEngine
LanguageEnglish

Related product manuals