ERROR CODE
COMMENTS / PROBLEM LOCATION
PROGRAM DESCRIPTION POSSIBLE ACTION CONSEQUENCE
C010
TIPPING LOCK OPEN IS 1 AND TIPPING LOCK CLOSED IS 1 HOOKLIFT
INPUTS CONFLICT 4 CHECK TIPPING LOCK OPEN AND TIPPING LOCK CLOSED
SENSORS - REPLACE IF NECESSARY
C011
JOYSTICK VALUE TOO SMALL CONTROL BOX
JOYSTICK CONFLICT CALIBRATE JOYSTICK - REPLACE IF NECESSARY
C012
JOYSTICK VALUE TOO BIG CONTROL BOX
JOYSTICK CONFLICT CALIBRATE JOYSTICK - REPLACE IF NECESSARY
C013
JOYSTICK HIGH VALUE WITHOUT DIRECTIONAL SWITCH,
CENTER TAPP IN MIDDLE
CONTROL BOX
JOYSTICK CONFLICT CALIBRATE JOYSTICK, CHECK WIRES - REPLACE IF
NECESSARY
C014
JOYSTICK LOW VALUE WITHOUT DIRECTIONAL SWITCH,
CENTER TAPP IN MIDDLE
CONTROL BOX
JOYSTICK CONFLICT CALIBRATE JOYSTICK, CHECK WIRES - REPLACE IF
NECESSARY
C015
JOYSTICK HIGH VALUE WITHOUT DIRECTIONAL SWITCH,
CENTER TAPP NOT IN MIDDLE
CONTROL BOX
JOYSTICK CONFLICT CALIBRATE JOYSTICK, CHECK WIRES - REPLACE IF
NECESSARY
C016
JOYSTICK LOW VALUE WITHOUT DIRECTIONAL SWITCH,
CENTER TAPP NOT IN MIDDLE
CONTROL BOX
JOYSTICK CONFLICT CALIBRATE JOYSTICK, CHECK WIRES - REPLACE IF
NECESSARY
C017
JOYSTICK VALUE 255 CONTROL BOX
JOYSTICK CONFLICT CHECK JOYSTICK WIRES (GND) - REPLACE IF NECESSARY
C018
JOYSTICK VALUE 0 CONTROL BOX
JOYSTICK CONFLICT CHECK JOYSTICK WIRES (SUPPLY VOLTAGE / SIGNAL)
- REPLACE IF NECESSARY
C019
CENTER TAPP NOT IN MIDDLE CONTROL BOX
JOYSTICK CONFLICT CHECK JOYSTICK WIRES (CENTER TAPP)
- REPLACE IF NECESSARY
C020
INPUT PRESENT AT START UP CONTROL BOX
SWITCH CONFLICT DO NOT PRESS SWITCHES WHILE CONTROL BOX IS
STARTING / CHECK AND REPLACE FAULTY SWITCHES