ERROR CODE
COMMENTS / PROBLEM LOCATION
PROGRAM DESCRIPTION POSSIBLE ACTION CONSEQUENCE
F010
not used
F011
(* Main cylinder oating short cut 2024
SHORT CIRCUIT CHECK THE CABLES
F012
(* Main cylinder oating voltage when not controlled 2024
Voltage when not controlled CHECK THE CABLES
F013
(* Main cylinder in 1 short cut 2024
SHORT CIRCUIT CHECK THE CABLES
F014
(* Main cylinder in 1 voltage when not controlled 2024
Voltage when not controlled CHECK THE CABLES
F015
(* Main cylinder in 2 short cut 2024
SHORT CIRCUIT CHECK THE CABLES
F016
(* Main cylinder in 2 voltage when not controlled 2024
Voltage when not controlled CHECK THE CABLES
F017
(* Main cylinder out 1 short cut 2024
SHORT CIRCUIT CHECK THE CABLES
F018
(* Main cylinder out 1 voltage when not controlled 2024
Voltage when not controlled CHECK THE CABLES
F019
(* Main cylinder out 2 short cut 2024
SHORT CIRCUIT CHECK THE CABLES
F020
(* Main cylinder out 2 voltage when not controlled 2024
Voltage when not controlled CHECK THE CABLES