TM1215 Iss. 6.0 RPR750
Stage Duration Alert
1 4 seconds LED flash only, following the
assigned beep code pattern
2 4 seconds LED flash and quiet tone, both
following the assigned beep code
pattern
3 8, 16, 32 seconds, or
continuous
As per stage 2, but at normal tone
volume
Table 3: Escalating Alert Sequence
2.4.9 Extended Alert
Extended Alert is a software programmable mode, which is entered if a call is not
cancelled within the normal alert period. The sequence is as follows: -
LED - one 0.125s flash, commencing 2s after the end of the normal alert period, followed
by one flash every 2s thereafter, until cancelled.
Tone - two 0.125s normal volume pips, commencing 120s after the normal alert period
and 2 further pips every 120s thereafter, until cancelled. The time period between the pips
is 2s and they are synchronised to the LED flashes. If the pager is in Mute mode, or the
call is a Silent Alert, then the pips will be suppressed.
Vibrate - one 2s vibration, commencing 120s after the end of the normal alert period,
followed by further vibrations every 120s, until cancelled.
Notes:
(a) It is not possible to interrogate ON/MUTE status, or change modes, during an
extended alert. The alert must first be cancelled and the call viewed from
memory.
(b) The 120s alert interval is programmable from 2 to 512s, although 120 and 300
seconds are the most commonly used.
2.4.10 On/Mute Mode
A software programmable option with User definable configurations, using the MUTE
button. Whilst in the Mute mode the pager will respond to calls, but will not emit a tone
alert, or activate the speech audio channel. An alert will be notified by the flashing LED
and vibration where activated. Text messages will be displayed and stored, as will any
associated speech messages, up to the specified storage limit. The Mute mode will be
neutralised by any override beep codes received and a normal alert will be sounded.
The ON/MUTE mode configuration may be changed, by pressing and holding the MUTE
button for 1.5s whilst the pager is in the quiescent state. Each status will be displayed and
acknowledged with an audible alert, in accordance with the Table 4 below. Subsequent
pressing of the MUTE button for 1.5s, will cause the pager to cycle through the status
options as given in Table 4.
Status On Display Audio Acknowledgement
on
1 quiet pip
Mute + vibrate
2 quiet pips + 1 second vibrate
On + vibrate
1 quiet pips + 1 second vibrate
Table 4: Mute/On Mode Sequence
13