IceDry800/1400
ItemDescriptionFunction
7ReactivationHeater(Stage2)IndicatorTheindicatorisonwhentherelevantheaterstageisswitched
on.Theindicatorwillashtoindicateaheater(stage2)fault.
8ProcessAirFanIndicatorTheprocessairfanindicatorisonwhenthefanisrunning.The
indicatorwillashtoindicateafault.
9DrivemotorindicatorThedrivemotorindicatorisonwhentherotordrivemotoris
operating.Theindicatorwillashtoindicateadrivemotorfault.
10Notapplicable
11Notapplicable
12FaultwarningindicatorWhenthefaultwarningindicatorisashing,itindicatesthat
theunithasshut-downduetooneofthefollowingfaultsbeing
detected:
-Processairfanfault
-Reactivationairfanfault
-Drivemotorfault
-Electricreactivationheater(stage1)fault
-Electricreactivationheater(stage2)fault
Toassistwithfaultdiagnosis,thecorrespondingindicatorwill
beashing.
Inadditiontheremotefaultoutputrelaywillbeactivated-
generalindication.
Forfurtherdetailsrefertosection7,Faulttracing.
13UnitrunningindicatorIndicatesthattheunitisrunning.
14PowerConnectedindicatorIndicatesthatmainpowerhasbeenconnectedtothe
dehumidierandthemainpowerswitchisinthe“1”position.
Table5.1Functionsforoperatorpanel.
18Operation190TGB-1037-G1307