User manual 55530_hdb_en_16 86 / 156
IO-Link event
integration
Fig. 8-24: IO-Link event integration
Type of allocation of IO-Link events to PROFINET diagnostics
Tab. 8-21: IO-Link event integration
Selection Meaning
D = Default
According to IO-Link integration
guideline Edition 1
Standardized IO-Link events are depicted
on standardized PROFINET diagnostics.
Murrelektronik IO-Link integration
Depiction of the IO-Link event number with
the help of mathematical processes on
PROFINET diagnostics.
Events of Murrelektronik devices are avail-
able in plain text.
Murrelektronik IO-Link extended in-
tegration D
Depiction of the IO-Link event number with
the help of mathematical processes on
PROFINET diagnostics.
Events of Murrelektronik devices are avail-
able in plain text.
Channel information is available for Mur-
relektronik devices that supports this.