Page #4 background image
RJ-900X series INSTALLATION MANUAL
RJ900XE-I-00
4
Detaching protective materials3.3
This product has protective materials in the
place shown below.
Detach all protective materials in accordance
with the following steps.
Remove all tapes from each cover.
1.
Open the front cover and unscrew the but-
2.
terfly screws, and detach the fixing head unit
protective materials (metal plate).
This completes detaching protective materials.
Installation4
Procedures and environment for installing this
product are explained.
Installation environment4.1
Install this product to the appropriate place with
reference to the following.
Do not install the printer in the follow-
z
ing places where there is a possibility
that the printer may be damaged or
might fall or be fallen by chance.
On a shaky stand
Slanting location
Places where vibration of other ma-
chines etc. is transmitted.
Do not stamp on the printer or do
z
not place heavy things on top of it. It
may cause an injury if the printer falls
down.
Cover the printer with blanket and
z
cloth like tablecloth and do not close
the vent . If the vent is closed, the
printer could accumulate heat inside
and may cause fire.
Do not install the printer in a location
z
that has high humidity or is dusty. It
could lead to electric shock and fire.
Installation environment4.1.1
Select an installation location in accordance
with the table below.
For temperature and humidity, avoid locations
z
such as the following. There is a possibility
that the print quality will be affected.
Places where temperature or humidity may
rapidly change, even though within the re-
quired conditions.
Place that receives direct sunlight or strong
illumination light
Place that receives direct wind from an air
conditioner, and so on
To keep the temperature and humidity con-
z
stant, install this product in a location where
the air condition is adjstable.
Installation space4.1.2
When using the printer with the stand
Install on a level floor which meets the following
condition.
It has enough strength to support the weight
of the printer and the stand.
For the weight of the printer and the stand,
z
refer to the Operation Manual.
When using the printer only (RJ-901X)
Install on a level table that meets the following
conditions.
The table has enough strength to support the
weigh of the printer.
For the weight of the printer, refer to the Op-
z
eration Manual.
The required length for the sheet media is
available in the back.
The height from the f loor is 600 mm to
800mm.
The space in the front is more than 300 mm.
Printed sheets are not folded or dirtied.
B
C
D
E
F
3+9
BNN
CNN
DNN
ENN
FNN
3+9
BNN
CNN
DNN
ENN
FNN
E
C
D
F
B
G
B
NN
CNN
DNN
ENN
FNN
GNN
Floor strength of instal-
lation place
More than 2940 Pa (300 kg/m
2
)
Power
Specifica-
tion
Power Sup-
ply
AC90V - 132V/198V - 264V
Frequency
Range
50/60Hz ±1Hz
Power
capacity
More than 10 A
Environ-
mental
conditions
Operative
condition
Temperature:10 °C-35 °C
Humidity: 20 % - 80 %, No Condensation
Guaranteed
range of
printing
accuracy
Temperature:15 °C - 28°C
Humidity: 40 % - 60 %, No Condensation
Change rate Temper
ature: within 2 °C per hour
Humidity: within 5 % per hour
No. Name No. Name
1 Fixing head unit protec-
tive materials (metal
plate)
2 Butterfly screw
NOTE
NOTE
W ARNING
NOTE