17. OTHER DRYER CHECKS & NON-SERVICEABLE ITEMS
DAILY CHECKS
Visual and funconal check of the dryer should be carried out daily:
• Check the dryer for any external damage.
Assess and eliminate any defects found.
• If the red service light appears, the dryer must be serviced.
Contact the service department and request required service kit.
• Remove any loose dust or dirt from the dryer; clean all surfaces that appear to have aracted unwanted con
taminants.
• Check the dewpoint sensor display (where applicable). If the dew point is not achieved the dewpoint
reading on the display will alternate with “dewpoint alarm” every 5 seconds. The no-volt alarm will also ac
vate.
Contact the service department and request a product service.
MAINTENANCE GUIDELINES
• Maintenance operaons only to be conducted when the system has been shut down and fully
depressurised.
• All connecons must be undone with care, paying parcular aenon to the areas that become
pressurised.
• Do not modify or adjust the control sengs.
• Only cered Nano-porous soluons approved replacement parts to be used.
• Always check all connecons for leakage and secure seang.
• Ensure all loose parts are removed or secured to the dryer before operaon.