17. OTHER DRYER CHECKS & NON-SERVICEABLE ITEMS
DAILY CHECKS
Visual and funconal check of the dryer should be carried out daily:
Check the dryer for any external damage.
Assess and eliminate any defects found.
If the red service light appears, the dryer must be serviced.
Contact the service department and request required service kit.
Remove any loose dust or dirt from the dryer; clean all surfaces that appear to have aracted unwanted con
taminants.
Check the dewpoint sensor display (where applicable). If the dew point is not achieved the dewpoint
reading on the display will alternate with “dewpoint alarm” every 5 seconds. The no-volt alarm will also ac
vate.
Contact the service department and request a product service.
MAINTENANCE GUIDELINES
Maintenance operaons only to be conducted when the system has been shut down and fully
depressurised.
All connecons must be undone with care, paying parcular aenon to the areas that become
pressurised.
Do not modify or adjust the control sengs.
Only cered Nano-porous soluons approved replacement parts to be used.
Always check all connecons for leakage and secure seang.
Ensure all loose parts are removed or secured to the dryer before operaon.