Remote control 7-7
?TAT This query command #?TAT * sends back a string expressing MinAtt value. The
reply is a string representing the minimum reachable value of attenuator in dB
Example of reply: TAT=10 which means that MinAtt is 10dB
?TMP This query command #?TMP* sends back a string showing the temperature
expressed in Celsius (°C) .
Example of reply: TMP= 40.50
?UHT This query command #?UHT* sends back a string expressing the actual hold time
currently or lastly used
Example of reply: UHT=1.9ms
?UPP This query command #?UPP* sends back a string expressing the status of input
PIN of the User Port.
Example of reply: UPP= 1 means that user port pin is high level