Importer Plus Technical Instruction Manual Description
Issue 0.02 2010-03-29 Page 1-5
Cooling requirements
This section provides information about heating and cooling requirements for the Importer Plus.
• Do not allow the Importer Plus room ambient air temperature to exceed 30°C (86°F)at sea
level. De-rate 3ºC (5.4°F) per 500 m – or 2ºC (3.6°F) per 1,000 feet – above sea level.
Example:
At 1,600 m (1 mile) above sea level, maximum ambient temperature should not exceed
20.4°C (67°F). Cooler temperatures are recommended, in order to improve the reliability of
the Importer.
• Do not install the Importer Plus next to other warm equipment.