Condition/Problem Things to Check Solution
No display/partial display/
unit will not turn on
Checkelectrical(wall)
outlet
Make sure unit is plugged into a functioning wall outlet. Test the
outlet with a known functioning device such as a lamp.
Check connection at front
of unit
Connection should be secure and undamaged. Replace power
cord or connection at unit if either are damaged.
Check data cable integrity All wires in cable should be intact. If any are visibly crimped or
cut, replace cable.
Check data cable
connections/orientation
Be sure cable is connected securely and oriented properly.
Small latch on connector should line up and snap into place.
Check console display for
damage
Check for visual sign that console display is cracked or other-
wise damaged. Replace Console if damaged.
Console Display IfConsoleonlyhaspartialdisplayandallconnectionsarene,
replace the Console.
If the above steps do not resolve the problem, contact Cus-
tomer Care for further assistance.
Unit operates but Contact
HR not displayed
Sensor grip Be sure hands are centered on HR sensors. Hands must be
kept still with relatively equal pressure applied to each side.
Dry or calloused hands Sensorsmayhavedifcultywithdriedoutorcallousedhands.
Aconductiveelectrodecream(heartratecream)canhelp
make better conduct. These are available on the web or at
medicalorsomelargertnessstores.
If tests reveal no other issues, contact Customer Care for fur-
ther assistance.
Unit operates but
Telemetric HR not
displayed
Chest Strap Strap should be “POLAR
®
” compatible and uncoded. Make
sure strap is directly against skin and contact area is wet. Make
sure the transmitter has the curve oriented upward.
Chest Strap Batteries If strap has replaceable batteries, install new batteries.
CheckUserProle SelecttheEditUserProleoptionfortheUserProle.Goto
the WIRELESS HR setting and make sure that the current
value is set to ON.
Interference Try moving unit away from sources of interference (TV, Micro-
wave,etc).
Replace Chest Strap If interference is eliminated and HR does not function, replace
strap.
Replace Console If HR still does not function, contact Customer Care for further
assistance.
Speed display is not
accurate
Display set to wrong unit
of measure. (English/
Metric)
Change display to show correct units.
TROUBLESHOOTING

Other manuals for Nautilus T616

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nautilus T616 and is the answer not in the manual?

Nautilus T616 Specifications

General IconGeneral
Maximum speed19.3 km/h
Number of programs26
Maximum user weight136 kg
Built-in displayYes
Weight and Dimensions IconWeight and Dimensions
Depth1960 mm
Width894 mm
Height1463 mm
Weight97500 g
Running area (W x L)508 x 1524 mm

Related product manuals