Troubleshooting 115
5.1.22 594Error
Error occurrence conditions and check items
Error Description
E594 error If the communication is abnormal in parts of PCB, the system displays E594 on the PCB.
Check items
1. Check the PCB.
Check method
Fault Possible Causes Check method
E594 Error
Abnormal
communication by
PCB.
1. Click the Reset button on Front panel.
2. Turn the POWER to the unit OFF then ON. Disconnect then reconnect power if
necessary.
3. If the system still displays E594, replace the main PCB.
5.1.23 615Error
Error occurrence conditions and check items
Error Description
E615 error Abnormal signal input by PCB.
Check items
1. Turn the POWER RESET switch OFF then ON (or unplug and replug the power supply.
2. If the system still displays E615, replace the main PCB.

Table of Contents

Other manuals for Navien NPE-240A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Navien NPE-240A and is the answer not in the manual?

Navien NPE-240A Specifications

General IconGeneral
TypeTankless
Fuel TypeNatural Gas or Propane
Energy Factor0.97
Energy Efficiency97%
Voltage120V
Ignition TypeElectronic
Maximum Input199, 900 BTU/h
Water Connection Size3/4"
Gas Connection Size3/4"
Warranty15-year on heat exchangers, 5-year on parts, 1-year on labor
Dimensions17.3" W x 13.2" D x 27.4" H