EasyManuals Logo

Navien NPE-240A Service Manual

Navien NPE-240A
171 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #69 background imageLoading...
Page #69 background image
Version 2.21
68 NPE Service Manual
4.11.11 Flow Sensor
Part Check Point
Function To detect water flow in GPM (Gallons Per Minute) for steady hot water temperatures.
Failure Event
1. Unable to detect or measure water flow rate.
2. Damage to and/or water leakage from the water flow sensor.
Effects Ignition sequence does not start.
Error Code E439
Diagnostic
1. Visual inspection: Connection and/or breakage of wires.
2. Visual Inspection: Check for damage and/or scale formation on sensor.

Table of Contents

Other manuals for Navien NPE-240A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Navien NPE-240A and is the answer not in the manual?

Navien NPE-240A Specifications

General IconGeneral
TypeTankless
Fuel TypeNatural Gas or Propane
Energy Factor0.97
Energy Efficiency97%
Voltage120V
Ignition TypeElectronic
Maximum Input199, 900 BTU/h
Water Connection Size3/4"
Gas Connection Size3/4"
Warranty15-year on heat exchangers, 5-year on parts, 1-year on labor
Dimensions17.3" W x 13.2" D x 27.4" H

Related product manuals