Version 2.21
36 NPE Service Manual
You can adjust the temperature by the below 10-degree
increments, depending on the temperature range:
Temperature range
Adjusting the water
temperature
98°F-120°F (Fahrenheit mode)
36°C-50°C (Celsius mode)
1°F or 0.5°C increments
120°F-140°F (Fahrenheit mode)
50°C-60°C (Celsius mode)
Press the + or - buttons for
2 seconds to adjust in 5°F or
2°C increments
The water heater will not provide hot water instantly at the hot
water faucet unless a recirculation line has been installed from
the furthest fixture back to the water heater and the unit is set to
external recirculation mode.
4.7.3 Using Commercial Mode
To use water above 140°F (60°C) (up to 182°F (83°C)), you can use
Commercial Mode.
To enter Commercial Mode: Press the up (+) and down (-) button
simultaneously for 10 seconds. “HIGH” appears on the display.
To exit Commercial Mode: Press the up (+) and down (-) button
simultaneously for 10 seconds. “LoW appears on the display.
NOTE
To adjust the temperature, press the up (+) button for
5 seconds to adjust in 10°F (5°C) increments.
Commercial Warranty Applies when this mode is used. Refer
to the Warranty for more details.
4.7.4 Viewing Basic Information
To view information about the water heater, press the Information
button.
Press the + or – buttons to switch between the information types.
Display Description
Flow rate in gallons per minute
(GPM).
Hot water outlet temperature (OUT).
Cold water inlet temperature (IN).
To exit information mode, press the Reset button.
4.7.5 Resetting the Water Heater
If an error message appears, you can try resetting the water heater
to resolve the problem. To reset the water heater, press the Reset
button.
If resetting the water heater does not solve the problem, refer to
the Troubleshooting section of this manual or contact Technical
Support at 1-800-519-8794.

Table of Contents

Other manuals for Navien NPE-240A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Navien NPE-240A and is the answer not in the manual?

Navien NPE-240A Specifications

General IconGeneral
TypeTankless
Fuel TypeNatural Gas or Propane
Energy Factor0.97
Energy Efficiency97%
Voltage120V
Ignition TypeElectronic
Maximum Input199, 900 BTU/h
Water Connection Size3/4"
Gas Connection Size3/4"
Warranty15-year on heat exchangers, 5-year on parts, 1-year on labor
Dimensions17.3" W x 13.2" D x 27.4" H