Version 2.21
118 NPE Service Manual
5.2 Troubleshooting guide by symptom
5.2.1 Noise
Error type Cause Check method
Vibration noise
Defective installation
Incorrect mounting to the wall or in an improper location.
Check for improper installation and reinstall the unit if necessary.
Fan vibration noise
Vibration caused due to defective blower.
Check the blower. If vibration is significant, replace the fan.
If intermittent noise occurs during operation, check the fan for debris.
If vibration noise occurs during operation of the product, and stops when the case
lid is removed, check the fan.
Regular noise
Defective flow sensor Rotating noise due to debris caught in the flow sensor.
Malfunction of water
adjustment valve
Noise due to repeated opening/closing of water adjustment valve due to a defective
PCB.
Noise at ignition
Gas and air differential
pressure error
(Pop, Beep, Explosive
ignition)
1. Offset pressure adjustment error (refer to page 29)
Adjust offset pressure with the pressure adjusting screw on the main gas valve.
Set the PCB DIP 4-switch to 1-OFF,2-ON (low fire) or use the Front Panel to set the
unit at "MIN.1" (refer to page 40).
If noise occurs at standard value, adjust setting above/below the standard.
2. Gas supply error due to defective air pressure sensor.
3. If the same error is repeated, it is due to a defective PCB.
Noise during
combustion
Boiling noise
How to check boiling:
Boiling occurs if the water temperature rises to149°F ~167°F(65°C~75°C).
The heat exchanger is clogged partially due to scale deposits. Flush the main heat
exchanger to remove scale.
Replace the heat exchanger if the error occurs from the start of the installation.
Whirring
Exhaust gas that is recirculated into the water heater through the air inlet could
produce abnormal combustion noises.
Check the distance between intake and exhaust (at least 12" (300mm)).
Check the distance between flues if two or more units are installed (at least 12"
(300mm)).
Check if there are any obstructions near the flue.
Low gas pressure
(whirring)
1. Noise occurs due to low gas pressure.
Check the gas supply pressure (dynamic pressure)
2. Low gas supply due to offset pressure error. (refer to page 29)
Set the PCB DIP 4-switch to 1-OFF,2-ON (low fire) or use the Front Panel to set the
unit at "MIN.1" (refer to page 40).
Noise due to defective air pressure sensor.
Replace the air pressure sensor.
Noise during
combustion
Noise due to damaged air pressure hose.
Noise may be intermittent depending on the size of the damage.

Table of Contents

Other manuals for Navien NPE-240A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Navien NPE-240A and is the answer not in the manual?

Navien NPE-240A Specifications

General IconGeneral
TypeTankless
Fuel TypeNatural Gas or Propane
Energy Factor0.97
Energy Efficiency97%
Voltage120V
Ignition TypeElectronic
Maximum Input199, 900 BTU/h
Water Connection Size3/4"
Gas Connection Size3/4"
Warranty15-year on heat exchangers, 5-year on parts, 1-year on labor
Dimensions17.3" W x 13.2" D x 27.4" H