Troubleshooting 119
5.2.2 Water Temperature Issue
Error type Cause Check method
Water heater is not
operating properly.
Front panel power off Hot water does not run if the front panel is switched off.
Defective flow sensor
The water heater does not work due to the defective flow sensor.
The flow sensor impeller will not rotate if it contains excessive scale or debris. Clean
out the flow sensor if possible.
If the impeller rotates normally, replace the flow sensor back into the water heater.
The sensor may be reused temporarily after cleaning, but replacement is
recommended.
Defective hot water
temperature sensor
The temperature is sensed higher than the actual temperature due to a defective hot
water (cold water) sensor.
Hot water temperature is low although hot water is recognized by the water heater.
The cold water temperature sensor may not work be working properly.
Low hot water
temperature
Hot water setting error Check the hot water temperature setting on the front panel.
Water mixed with cold
water.
The temperature of hot water at the tap is low while the temperature is high at the hot
water outlet.
Cold water and hot water are mixed due to improper pipe installation.
Cold water and hot water are mixed due to improper piping at the hot water faucet.
No hot water from the
valve
Check the pipe
1. The cold water valve is closed.
2. Check if the cold water filter is clogged with foreign substance.
3. The water adjustment valve is closed. (Refer to E434 on page 102)
4. Check if the cold water / hot water pipes are frozen during the winter.
5. The main heat exchanger is clogged (by scale).
6. Low inlet water pressure
Cold water flows
temporally
Pre-heating does not
work
For the A model, the system initiates the internal/external circulation preheating when
a recirculation mode is selected on the front panel DIP switches. Confirm the DIP
switch settings.

Table of Contents

Other manuals for Navien NPE-240A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Navien NPE-240A and is the answer not in the manual?

Navien NPE-240A Specifications

General IconGeneral
TypeTankless
Fuel TypeNatural Gas or Propane
Energy Factor0.97
Energy Efficiency97%
Voltage120V
Ignition TypeElectronic
Maximum Input199, 900 BTU/h
Water Connection Size3/4"
Gas Connection Size3/4"
Warranty15-year on heat exchangers, 5-year on parts, 1-year on labor
Dimensions17.3" W x 13.2" D x 27.4" H