5.2.3 Circuit breaker operation
Error type Cause Check method
Circuit breaker trips
Power supply
The circuit breaker trips immediately as soon as the power cord is plugged in the
receptacle.
Check the sheath of power cord, or if there is short-circuit.
Check the components in order from the power transformer to the PCB.
Defective part
assembly
If the circuit breaker operates after repairs check the wiring of each part.
Maintain proper direction when assembling the ignition transformer.
Be careful that wire is not compressed when assembling the main gas valve
Check if the wire is fixed and properly attached on the main side of the heat exchanger.
Normal assembly
Short-circuit due to defective assembly Wiring near the heat exchanger
Circuit breaker
operates while
the water heater is
running
If circuit breaker trips during the operation of the water heater, check the order of
operation, and replace the concerned part.
e.g., The circuit breaker operates at switchover to burner stage 2after ignition.
Replace the dual venturi.
Remote controller
power
Check the wire
Check the power supply to the remote controller terminal. (DC 19 V or higher).
If there is a problem in power supply, check the output voltage of the PCB, and take the
action separately for wiring error and defective PCB, respectively.
If the power supply is normal, replace the remote controller.

Table of Contents

Other manuals for Navien NPE-240A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Navien NPE-240A and is the answer not in the manual?

Navien NPE-240A Specifications

General IconGeneral
TypeTankless
Fuel TypeNatural Gas or Propane
Energy Factor0.97
Energy Efficiency97%
Voltage120V
Ignition TypeElectronic
Maximum Input199, 900 BTU/h
Water Connection Size3/4"
Gas Connection Size3/4"
Warranty15-year on heat exchangers, 5-year on parts, 1-year on labor
Dimensions17.3" W x 13.2" D x 27.4" H

Related product manuals