Version 2.21
22 NPE Service Manual
10-switch Panel:
Switch Function
Setting
Remark
A models
(NPE-180A/ 210A / 240A)
“S” models
(NPE-150S/180S/210S/240S)
DIP switch setting
1-3
Recirculation
Mode- Internal
Navien Pump
("A" models only)
No Recirculation 1-OFF; 2-OFF; 3-OFF
* Intelligent Preheating:
Learns the user's hot water
usage patterns and starts
preheating prior to an
anticipated draw.
Preheating starts when
remote controller is not
connected.
When remote controller
is connected, preheating
starts and operates based
on the timer.
Set the timer on the
remote controller to use
hot water at the time of
your choice.
Intelligent preheating does
not function in Cascade
Mode (Preheating OFF).
Freeze protection is still
available with preheating
OFF.
When installing an NPE
water heater with NR,
NP or CH series units
for a cascade system,
temperatures are displayed
in Fahrenheit only.
For NPE“S” models,
preheating is not available
when using a cascade
configuration.
**External Pump:
These settings are to be used
when an external pump is
wired to the water heater.
***Lime Alarm:
Displays a "760" error when
the set time period has been
reached to indicate a flush or
service is necessary.
****High Altitude
Above 2,000ft (610m), the
water heater will de-rate by
4% for each 1,000ft (305m)
of altitude gain.
Internal Recirculation No Recirculation 1-ON; 2-OFF; 3-OFF
External Recirculation No Recirculation 1-OFF; 2-ON; 3-OFF
Intelligent Preheating* No Recirculation 1-ON; 2-ON; 3-OFF
Recirculation
Mode-
External Pump
Connected**
External Pump Only 1-OFF; 2-OFF; 3-ON
External Recirculation External Pump Only 1-ON; 2-OFF; 3-ON
External Recirculation External Pump Only 1-OFF; 2-ON; 3-ON
Intelligent Preheating*
Intelligent Preheating*
(External Pump Only)
1-ON; 2-ON; 3-ON
4
Display
Temperature Unit
Celsius (with L/M) 4-ON
Fahrenheit (with GPM) 4-OFF
5 Well Pump
Well Pump Operation 5-ON
Do Not Use Well Pump 5-OFF
6
DHW Storage
Tank/Solar
System
Storage Tank/Solar System Operation 6-ON
Do Not Use Storage Tank/Solar System 6-OFF
7 & 8 Lime Alarm***
Off 7-OFF; 8-OFF
6 Months Alert 7-ON; 8-OFF
12 Months Alert 7-OFF; 8-ON
24 Months Alert 7-ON; 8-ON
9 & 10
High Altitude ****
(Applies to Main
PCB version V1.4
(July 11, 2013) or
later versions only)
0 ~ 1,999 ft (0 ~ 609 m) 9-OFF, 10-OFF
2,000 ~ 5,399 ft (610 ~ 1,645 m) 9-ON, 10-OFF
5,400 ~ 7,699 ft (1,646 ~ 2,346 m) 9-OFF, 10-ON
7,700 ~ 10,100 ft (2,347 ~ 3,078 m) 9-ON, 10-ON

Table of Contents

Other manuals for Navien NPE-240A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Navien NPE-240A and is the answer not in the manual?

Navien NPE-240A Specifications

General IconGeneral
TypeTankless
Fuel TypeNatural Gas or Propane
Energy Factor0.97
Energy Efficiency97%
Voltage120V
Ignition TypeElectronic
Maximum Input199, 900 BTU/h
Water Connection Size3/4"
Gas Connection Size3/4"
Warranty15-year on heat exchangers, 5-year on parts, 1-year on labor
Dimensions17.3" W x 13.2" D x 27.4" H