92 NPE Service Manual
Check method
Fault Possible Causes Check method
Heat exchanger
overheated
Damaged or clogged
heat exchanger
1. The error occurs due to high exhaust gas temperature caused by a damaged or
clogged heat exchanger.
2. Flush the heat exchanger to remove scale deposits.
3. Replace the heat exchanger if it is damaged or cannot be unclogged.
Defective part
Defective overheat
controller
Defective contact point of the exhaust gas overheat controller 230°F (110°C) Max
Check connection of the overheat controller.
If the resistance is abnormal, replace the temperature sensor. (refer to page 60)
Check the output temperature displayed on the PCB.
Check if the hot water temperature sensor is open (Error type : M Open)
Other trouble Defective PCB If the issue continues despite checking the items above, replace the PCB.

Table of Contents

Other manuals for Navien NPE-240A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Navien NPE-240A and is the answer not in the manual?

Navien NPE-240A Specifications

General IconGeneral
TypeTankless
Fuel TypeNatural Gas or Propane
Energy Factor0.97
Energy Efficiency97%
Voltage120V
Ignition TypeElectronic
Maximum Input199, 900 BTU/h
Water Connection Size3/4"
Gas Connection Size3/4"
Warranty15-year on heat exchangers, 5-year on parts, 1-year on labor
Dimensions17.3" W x 13.2" D x 27.4" H