Troubleshooting 95
Check method
Fault Possible Causes Check method
Dual Venturi action
error
Defective Dual Venturi
cable or harness
1. Disconnect all cables from the Dual Venturi.
2. Using a multi-meter, test the Dual Venturi electrical wiring.
Dual Venturi not
operating
1. Turn off the power to the unit using the main power switch (do not use the front
panel power button) and wait for 10 seconds.
2. Turn on the power.
3. Wait until Fan Auto Adjusting is complete.
4. Enter the Dual Venturi Test Mode and perform a test.
1) Repeat the test at least twice. Turning the unit ON and OFF once makes one test
cycle. ON
OFF
ON
OFF
…… is the minimum sequence.
2) Confirm that the Dual Venturi is operating correctly.
a. Listen to the Dual Venturi while it is running and check for operational noise
(clicks at unit ON and unit OFF).
b. If operational noise cannot be heard because of ambient noise, disassemble
the Dual Venturi and perform a visual inspection.
5. If error message (E060) occurs, replace the Dual Venturi.
6. If a Dual Venturi error does not occur, replace the APS.

Table of Contents

Other manuals for Navien NPE-240A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Navien NPE-240A and is the answer not in the manual?

Navien NPE-240A Specifications

General IconGeneral
TypeTankless
Fuel TypeNatural Gas or Propane
Energy Factor0.97
Energy Efficiency97%
Voltage120V
Ignition TypeElectronic
Maximum Input199, 900 BTU/h
Water Connection Size3/4"
Gas Connection Size3/4"
Warranty15-year on heat exchangers, 5-year on parts, 1-year on labor