13 - 3
Standard Cable Pinouts
Laser Output Only (Laser Compatible Bar Image)
10 Pin Modular Plug
connects to the scanner handle
1 Turn on good read or LED beeper
2 Trigger signal to decoder
3 Laser enable
4 Supply ground
5
6 Digital bar code data output
7 Power connection (Refer to table on page 13-1)
8
9 Start of scan
10
Start of scan
Digital bar code data output
Turn on good read LED or beeper
◆
N/C
Trigger signal to decoder
9 Pin Type D Female
connects to your terminal
Laser enable
Supply ground
Cord shield
5 Volt power connection ◆
1
2
3
4
5
6
7
8
9
◆
Pins 4 and 9 are populated depending on power supply voltage option.
Some decoders may have +12V on pins 4 or 9. Connect to +5VDC ONLY!
Conventional laser data format is provided at the modular connector in the scanner handle. The inter-
face cable is terminated with a 10 pin modular plug, and a 9 pin Type D (squeeze to release) connec-
tor that is compatible with all NCR’s terminals.