3 - 5
read, or until the trigger is released." on page 3-4), or manually. After scanning
the Serial Trigger Time Out bar code, set the time out duration (from 0-1200
quarter seconds) by scanning digits from the inside back cover, then scanning
Save.
Default = 0 (infinite, or no time out).
Manual Trigger, Low Power:
The scanner “sleeps,” using only 30 milliamps,
until the trigger is pulled. When the trigger is pulled, the scanner wakes up and
operates at reduced power until there is no triggering for the time set with the
Low Power Time Out bar code. There is a short delay in operation when the
scanner is first triggered, but there is no delay when operating in low power
mode.
Note: Manual Trigger, Low Power cannot be used with keyboard wedge appli-
cations.
Low Power Time Out:
Scan the Low Power Time Out bar code to change the
time out duration. Then scan the time out duration (from 0-300 seconds) from
the inside back cover, and Save.
Default = 2 minutes.
Note: If you make an error while scanning the digits (before scanning Save),
scan Discard on the back cover, scan the Lower Power Time Out bar
code, scan the correct digits, then Save again.
Automatic Trigger:
The scanner scans continuously at full power.
Serial Trigger Time Out
Manual Trigger, Low Power
Low Power Time Out
Automatic Trigger