Installing a DSX Analog Door Box and 2PGDAD Module
60 ◆ Optional Equipment DSX-80/160 Hardware Manual
Mounting the 2PGDAD Module and Connecting to the System
To mount and connect the 2PGDAD Module:
1. Mount two suitable fasteners (such as #8 sheet metal screws) about 3 15/16” apart either horizontally (for
horizontal mounting) or vertically (for vertical mounting).
- Leave the heads exposed about 1/4”
2. Place the 2PGDAD Module over the screws and slide down into place.
3. Program the Door Box and 2PGDAD Module before connecting to the 2PGDAD modular jack.
- In 1203-01: Secondary Station Port Assignment, for the 16ESIU port selected enter an available
station port for the secondary port (96-127 by default).
- In 2113-02: Ring Group, assign the extensions associated with the 2PGDAD Module and all tele-
phones that should receive door chimes to the same Ring Group.
- Refer to the Door Box feature in the DSX Software Manual for additional programming.
4. Using a standard line cord, plug the 2PGDAD Module into its modular jack and verify the LEDs.
Figure 45: Mounting and Connecting the 2PGDAD Module
1093096 - 49
1
3
2
2
1
2
2
3
4
4