1 - 2 Electra Elite IPK IAD(8)-U( ) ETU
___________________________________________________________________________________
___________________________________________________________________________________
Document Revision 4 MEGACO Station
SECTION 2INDICATORS, SWITCHES, AND CONNECTORS
2.1 LED Indicators
A total of nine LEDs on this ETU are described in Table 1-1 Default Boot
Sequence: In Active IAD(8)-U10 ETU - Without IP Application Loaded.
2.1.1 Status LED
This LED chart shows the status of the IAD(8)-U( ) ETU during boot
up. The conditions change as the IAD(8)-U( ) ETU boots up and
passes through different boot states. This boot sequence will occur
with the IAD(8)-U10 ETU, when there is no IP Application loaded and
the card is at default.
Table 1-1 Default Boot Sequence: In Active IAD(8)-U10 ETU -
Without IP Application Loaded
State
D8
CH 1
D6
CH 2
D4
CH 3
D2
CH 4
D7
CH 5
D5
CH 6
D3
CH 7
D1
CH 8
D12*
LIVE
Approximate Time
1 OFF OFF OFF OFF OFF OFF OFF OFF FLASH 1 second
(from Cold Boot)
2 ON ON ON ON OFF OFF OFF OFF FLASH 5 seconds
3 OFF OFF OFF OFF OFF OFF OFF OFF FLASH 3 seconds
4 OFF OFF OFF OFF ON ON OFF OFF FLASH 5 seconds
5 OFF OFF OFF OFF OFF OFF ON ON FLASH 5 seconds
6 OFF OFF OFF OFF OFF OFF OFF OFF FLASH 5 seconds
* LIVE LED D12 also flashes when the ETU is receiving power from the KSU.