MEGACO Station Document Revision 4
Hardware, Installation and Maintenance Manual B - 3
___________________________________________________________________________________
___________________________________________________________________________________
Question:
The Electra Elite system does not recognize the IAD(8)-U( ) ETU (Megaco station)
and IP terminal and displays NO PORTS IN KTS.
Answer:
Make sure the Electra Elite system is programmed for the same card type using
Memory Block 7-1 (Card interface Slot Assignment) as the operating mode of the
IAD(8)-U( ) ETU. For example, if the IAD(8)-U( ) ETU is in slot 3 of cabinet 1 and
operating as a ESI(8)-U( ) ETU (Megaco Station ETU), the Electra Elite IPK system
must be programmed, using a PC or handset, for a ESI(8)-U( ) ETU (Megaco Station
ETU) in slot 3 of cabinet 1.
Verify that the IAD(8)-U( ) ETU SW2 settings are configured for ESI mode.
SECTION 3RETURNING THE IAD(8)-U( ) ETU (MEGACO STATION) TO DEFAULT
C
ONFIGURATION
To return the IAD(8)-U( ) ETU to the default configuration:
1. Remove the IAD(8)-U( ) ETU.
2. Set DIP Switches S2(1) ~ S2(8) in the ON position (factory default).
3. Replace the IAD(8)-U( ) ETU in the KSU.
4. When the bootup process is completed, the IAD(8)-U( ) ETU is restored to the
factory default configuration.
5. The IAD (8)-U( ) ETU Default IP Address is: 192.168.1.100. The subnet mask is
255.255.255.0.
6. Point the Internet Explorer (Version 5 or higher) on the PC to 192.168.1.100 by
typing this address in the navigation bar.
When you upload a package while in factory default mode, all configured data will
be lost, and default settings apply.