4 - 2 IPK IAD(8)-U( ) Configuration
___________________________________________________________________________________
___________________________________________________________________________________
Document Revision 4 MEGACO Station
SECTION 3SAMPLE SETUP PROCEDURE
To setup the IAD(8)-U( ) ETU:
1. Set the card type according to the settings specified in Table 1-3 IAD(8)-U( )
ETU Switches in Chapter 1 Electra Elite IPK IAD(8)-U( ) ETU on page 1-4 and
then install the ETU in the Electra Elite IPK KSU.
2. Boot up a client enabled PC that is connected to the same network as the
IAD(8)-U( ) ETU.
3. Connect to the IAD (8)-U( ) ETU via your Web Browser. Login to the IAD(8)-U( )
with the following:
Login ID = admin
Password = password
4. Set the IP Address, Subnet Mask, Computer Name, and Default IP parameters
in the IAD (8)-U( ) ETU configuration tab. Select Submit.
5. Set the Port settings fields to the desired operation: Encoding Preference,
Packet Size, Jitter Depth, and IP Address or DHCP selection for the IP
terminals.
6. When all parameters have been configured, select Submit.
7. Select the System tab, then select the Reset the Card option. The ETU goes
through a reboot cycle and may take a few minutes.
8. Disconnect the crossover cable and connect the IAD (8)-U( ) ETU to the LAN
port.
The ETU is now ready for operation, assuming that the Electra Elite IPK system
has been programmed to recognize this ETU. In system programming, use
Memory Block 7-1 (Card Interface Slot Assignment) to ensure that the operation
mode is set to ESI(8).
Table 4-2 Network Settings for the PC
IP Address
192.168.1.XXX
Subnet Mask
255.255.255.0

Other manuals for NEC Electra Elite IPK