Appendix
36
6. Appendix
Error code list
Please inquire your dealer/distributor about action to be taken for each error code.
Description is omitted for error codes 20 and on.
Error code
Error message description
1 Cover Open Cover is open.
2 Lamp Temp. Temperature (lamp temperature) is abnormal.
3 Fan Stop Fan has stopped.
4 Power Supply Power supply is abnormal.
5 Lamp Off Lamp does not light up.
6 LampTime Warn Lamp time is over. (Warning)
7 LampTime Over Lamp time is over. (Power off)
8 Lamp PS Temp. Temperature (lamp power inside temperature) is abnormal.
9 Set Temp. Temperature (set inside temperature) is abnormal.
10 DLP PS Engine power is abnormal.
11 DLP Comm TI-Engine communication error is detected.
12 Lamp Timer R Lamp Timer read error is detected.
13 Interlock Fail Inter Lock error is detected.
14 No Support Eng. DVI Dual Engine does not support.
15 Lamp Timer W Lamp Timer write error is detected.
20 System Fail
21 Self Test Fail
22 ARM Fail
23 DSP Fail
24 Interface FPGA Fail
25 Processor FPGA Fail
30 IB Diag Not Performed
31 IB FPGA Code Invalid
32 IB FPGA INITZ Fail
33 IB FPGA No-Load Set
34 IB FPGA DONE Fail
35 IB FPGA Reg R/W Fail
36 IB Framestore Test Fail
37 IB ANC FIFO Test Fail
38 IB RTC Serial # Fail
39 IB UART0 Fail