5-43
f. Open Menu(S), TAG C "H.CONVER PARA B", and adjusted so that misconvergence of the horizontal
direction may become the minimum in M of the Fig 10-7 and N and O point. Open Menu(S), TAG C
"V.CONVER PARA B", and adjusted so that misconvergence of the vertical direction may become
minimum.
H.CONVER PARA B V.CONVER PARA B
Fig 10-5 The move of the R line and the B line when "H./V. CONVER PARA B" was moved in the + direction.
3) Measure misconvergence, by using following standards mentioned below.
Adjusted to satisfy the standard of the Xv revision Coil on DY, XH slider ,Blue-BOW revision ring, 6-pole
magnets on the CPM, spoiler magnet.
* The installation lie of each VR and slider is shown in the Fig. 10-8,and actuation is shown in
the Fig.10-9.
* There is a deflecting yoke in a point to install the XH slider from side to side to side.
When it was imported in the left viewed from the screen side, Demonstrated in Fig.10-9-c.
When it was imported in the right viewed from the screen side, Demonstrated in Fig.10-9-d.
The value of standards : x , y
0.30mm
X
V
-COIL
6-pole magnets
4-pole magnets
TRD(LR)
Y
h
Fig 10-4 The location of the VR. and Coil and magnets